L-Shape Stone Slab Storage Rack for Upright Sheet Handling
For stone processors and building-material warehouses, the Grack configuration specified for project 15742 stores 4 × 8 ft panels upright in a 600 mm storage width. A 90° inner corner helps the panel sit against the rack, a controlled lean reduces tipping tendency, and integrated tie-down rings secure the load before the rack is moved. The reference unit is 2400 × 750 × 1200 mm and rated at 1000 kg per rack; final capacity must be checked against panel thickness and density.
Confirm Your Panel Rack Configuration
Stand the slab upright. Tie it before it moves.
A heavy flat panel stored on its edge has a concentrated centre of gravity. If the support face is too open, the panel can shift, lean further, or tip when operators pick one sheet from a group. Grack turns the storage position into a controlled support system: place larger panels at the rear and smaller panels in front, seat the lower edge in the rack, let the panel follow the inner 90° corner and rear support, then route the restraint through the fixed rope rings. This workflow suits marble, granite, acrylic, metal sheets and other rigid flat panels when the load, contact surface and handling method are confirmed in advance.
A defined rack footprint for 4 × 8 ft panels
The following values describe the 15742 reference configuration. Capacity is not a universal value for every board: confirm thickness, density, panel quantity, centre of gravity and handling equipment before release.
| Item | 15742 reference value | Use in planning |
|---|---|---|
| Application | Upright storage of 4 × 8 ft panels | Stone, acrylic, metal sheet and similar rigid flat panels |
| Overall dimensions | 2400 × 750 × 1200 mm | Check aisle, door and forklift clearance |
| Storage width | 600 mm, single side | Match the required panel group and loading sequence |
| Rated load | 1000 kg per rack | Verify against panel thickness and density before order |
| Rack tare weight | 112 kg | Include rack weight in handling and transport planning |
| Restraint | Integrated tie-down rings | Strap the panels before any rack movement |
| Rubber strip | Not required for the 15742 request | Use only when surface protection or non-metal contact is required |

Check the load before choosing the rack
Send the panel material, thickness, density or weight, maximum sheet size, quantity per rack and the planned forklift or pallet-truck route. We can then confirm whether the 1000 kg reference capacity and 600 mm storage width fit the actual load.
- Panel weight and centre-of-gravity review
- Storage width and aisle clearance check
- Restraint and surface-contact recommendation
Support the panel first. Restrain it before movement.
The rack addresses two separate risks: tipping during upright storage and load movement during transport. Both steps remain necessary.
90° contact plus a controlled lean reduces the tipping path
The inner 90° corner gives the panel a defined meeting point instead of a loose open support. The lower edge is seated in the base while the panel rests against the rear support with a slight lean from vertical. That geometry keeps the load against the rack and reduces the chance of a heavy sheet walking forward under its own weight. Load larger sheets behind smaller ones, keep the rack on a suitable level surface, and do not exceed the confirmed capacity. This is a storage-support principle, not a substitute for an operating risk assessment.

Tie-down rings make restraint part of the moving workflow
After loading, pass the rated strap through the rack’s fixed tie-down rings and tension it over the panel group so the sheets cannot shift when the rack is pushed, lifted or transferred. Tie-down is mandatory before movement; the 90° corner and lean alone do not secure a mobile load. Use straps and tensioning equipment suitable for the panel weight, protect edges where needed, and release the restraint only after the rack is parked and the load is stable.

When rubber strips are not required
The 15742 request specifies no rubber strip. That can be considered when the board’s edge and finish tolerate the defined contact, the process does not require anti-scratch isolation, and the customer accepts the contact condition. For glass, polished stone, coated metal, painted panels or any surface where edge pressure or metal contact is unacceptable, ask for a rubber profile, pad or another verified separator instead. The material and finish decide this option—not the rack name alone.
Choose the next planning step
Compare this upright storage configuration with the related PDP-05 handling option, use PAGE-02 for broader product planning, and return to SOCIAL-03 for the application story. For a project-specific recommendation, send the actual panel schedule and movement route to our team rather than selecting a capacity from a standard image.
Need a rack for heavy upright sheet storage?
Send your panel material, thickness, density or weight, quantity, required storage width and handling method. We will review the 15742 reference—2400 × 750 × 1200 mm, 600 mm storage width, 1000 kg per rack and 112 kg tare weight—and confirm the suitable configuration, restraint method and contact protection.