For a mixed sheet inventory from 2 mm to 25 mm, this Hrack solution focuses on the thin-sheet group from 2 mm to 10 mm. The layout uses wall-side rows and a back-to-back center block to raise storage density while keeping access safe and controlled.

racks in the center zone
single-slot clear width
maximum storage thickness per slot
The customer’s sheet inventory includes maximum dimensions of 1700 mm in height and 1900 mm in length, with a thin-sheet focus on 2 mm, 3 mm, 4 mm, 5 mm, 6 mm, 8 mm, and 10 mm material. The Hrack rack is used here as a controlled storage frame, not as a loose stacking method.
With wall-side racks placed along both sides and the back-to-back rack group positioned in the middle, the warehouse can keep forklift lanes open and still build a dense storage core. That makes the layout practical for daily picking, safe handling, and future expansion.
Thin sheets can bend, slide, or rub against each other when the storage bay is too wide or the contact points are too few. The layout must control the slot width, stabilize the load path, and preserve enough aisle space for smooth forklift movement.
Recommended storage and layout strategy
Use perimeter rows first
Place rack rows against the walls before filling the middle zone. This uses dead space efficiently and keeps the central aisle clear for loading, unloading, and inspection.
Build a back-to-back center block
Set the Hrack units back-to-back in the middle of the warehouse. In the provided plan, that arrangement supports 42 racks and still leaves room for more units or other operating functions.
Apply the thin-sheet operating limit
Use the 14 mm net slot width and the 12 mm maximum storage thickness as the working rule for thin sheets. This keeps the bundle stable and reduces side movement during handling.

Why this layout works on the floor
The case drawings show an assembled bolt-connected structure with multiple contact points for the stored sheets. That matters because thin material needs support and repeatable handling more than it needs a simple open bay. The proof set also shows that density can be improved without blocking future rack expansion.
Technical parameters
| Parameter | Value |
|---|---|
| Opportunity | 14823 |
| Maximum sheet size | 1700 mm (H) × 1900 mm (L) |
| Minimum sheet size | 650 mm (H) × 1350 mm (L) |
| Target thin-sheet range | 2 mm to 10 mm |
Operating safeguards
- Keep forklift entry and lifting movements smooth so the frame and sheet edges are not hit during loading.
- Check the base, uprights, and weld points regularly for bending, deformation, or cracks.
- When stacking statically, confirm the upper rack feet are fully seated on the lower uprights before releasing the load.
Engineering insight: Thin-sheet storage only stays stable when slot width, contact points, and aisle logic are designed together. Capacity without control creates damage risk; control without density wastes floor area.