Glass harp rack · WIP storage area · vertical storage
An A-frame bay holds a pack; a buffer between two machines holds whatever the furnace just pushed out. Measured as floor per position at partial fill, a 1,500 × 1,000 mm glass harp rack puts 40 slots on 1.5 m² and a 1,310 × 600 mm build puts 60 slots on 0.79 m², because vertical storage sets pitch along the base instead of spreading two lean angles across the aisle — the arithmetic behind how a harp rack for glass increases storage density in a compact WIP storage area, with slot width, base route, slot count and lock stations confirmed per order drawing.
The tempering furnace unloads in a batch. The IGU sealer draws one unit at a time. Between those two rhythms sits a piece of floor, and on that floor every shop puts whatever it already owns — usually an A-frame bay, because the A-frame is the rack everybody bought first.
That is the mismatch worth pricing. An A-frame is a good storage machine: one pack, one SKU, days at a time. A buffer is a different job. It is judged on three things — floor consumed per position when the rack is nowhere near full, whether lite number 7 comes out without moving lites 1 to 6, and whether the loaded rack stays where you parked it when you take your hand off it. A glass harp rack answers those three questions structurally, not by being taller.
The area account: what a lean angle costs per position
Take the bay drawing you already have. Each side of an A-frame leans, so the horizontal projection of a lite equals its height times the sine of that lean. On a 2,000 mm lite at a 6° lean, that is roughly 209 mm per side; add the pack across the base — 25 lites at 12 mm plus bearers lands near 380–400 mm — and the bay stands on something like 0.82 m deep by 2.0 m wide, about 1.6 m² for 25 positions. That is around 0.066 m² of shop floor per position, and it is only true at 100% fill. Load six lites into that bay and the same 1.6 m² carries six positions: 0.27 m² each.
A harp rack does not derive its pitch from a lean angle. Sheets stand upright in their own slot, bottom on the support line, upper face against the backrest, and the position spacing is set along the base beam. On recorded builds: a 1,500 × 1,000 mm base carries 40 slots for lites up to 12 mm with a 1,500 kg design intent, which is 0.0375 m² per position; a 1,310 × 600 mm base carries 60 slots on a 14.3 mm slot width and stands on 0.79 m², about 0.013 m² per position, and that same build packs to 141 × 114 × 20 cm, roughly 0.32 m³ and 88.2 kg. Wider 84-slot and 50-slot builds exist on other projects. The density comes from slot pitch, not from adding height — which is why the comparison has to be run per drawing rather than per catalogue.

Partial fill is the normal state, so the station has to hold four lites
Size a buffer on the difference between what arrives and what leaves, not on the shift total. If the furnace hands over a batch and the sealer takes units off it, the peak is the residue, maybe a dozen or twenty lites. A fifteen-slot residue parked on a pack-sized bay is unstrapped glass in a traffic lane; the same fifteen on a 40-slot slot line is a rack that is simply 40% full and still legal to leave standing. That is the peak-shaving argument, and it is a granularity argument: the A-frame counts in packs, the harp rack counts in slots, and a buffer is always part-loaded.
The second half is that a station must not move. Brake casters on a floor with cutting oil or slurry lose the friction the brake depends on, so the rack walks. The foot-pedal mechanical floor lock works the other way round: the pedal raises a plunger and lifts the base onto fixed pads, so the load no longer stands on four wheels. Some projects ask for one lock, some for two stations; caster sets are 5-inch or 8-inch polyurethane or nylon, normally 2 fixed and 2 swivel with brakes, and one project specified fixed casters on the stop-bar side with swivel at the front roller side. Those are drawing decisions, and they are what makes the difference between glass WIP buffer rack equipment that stays put and glass that drifts into an aisle.

Store and flow: give the A-frame the dock and the harp rack the twenty metres
None of this makes the A-frame wrong. It earns its floor where a finished pack sits for days waiting on a truck or a project release, because there the rack is a warehouse wall and the lean keeps the stack compact. The split that works is by dwell time: long-stay packs at the dock, short-stay lites at the furnace exit, the sealer, the laminating bench and the polishing line, each harp rack standing as its own station instead of one bay serving four processes. Where a shop needs density along a line, the line can nest — one recorded rack of 2,700 × 2,400 × 2,000 mm holds four 650 × 2,400 × 1,900 mm harp racks at 25 sheets each, 100 sheets total, and 25 sheets of 1,800 × 2,000 × 12 mm is about 2,500 kg, so the pushing force or a reserved fork lane has to be in the layout, not discovered on the floor.
The slot numbering scale is the small part that decides whether the buffer is addressable. A numbered index under the front roller shaft, or the sticker runs photographed from 01–23 up to 57–74 on a high-density build, turns “somewhere near the front” into a slot number that a second shift can also find. Contact surfaces follow the same logic: wire-core dividers inside a PVC sleeve, an EPDM backrest bolted to the frame, and on short or high non-standard lites a full steel slotted base with an HDPE slotted board so the bottom edge gets continuous support instead of two roller discs and air.

Four lines to send before the base is cut
- Slot width, per lite thickness. Recorded values run 8–10 mm for 6 mm lites, and 12 mm, 14 mm, 14.3 mm and 25 mm on other projects. A 6 mm lite in a 14 mm channel has travel to build up before it hits its neighbour; tell us the thickness mix and the slot width is drawn to it.
- Base route. Nylon roller shafts for mixed architectural work, or a full steel slotted base with an HDPE slotted board when the order is short, high, trapezoid or triangular and the bottom edge needs an unbroken line of support. One rack does not do both jobs well.
- Smallest and largest lite, both. A frame drawn around the biggest lite can make the smallest one awkward to reach, so the Q235A carbon steel structure, the slot count and the slot pitch are confirmed against both ends of the range, not the headline size.
- Lock stations and caster set. How many foot-pedal floor locks, 5-inch or 8-inch wheels, and which pair is fixed. Get this wrong and the station is a trolley again the first time someone leans on it.
