IGU assembly · kitting · random access
An insulating glass unit reaches the sealing table as a pair, yet a rack loaded in cutting sequence hands over one lite and buries its mate. How harp racks for sorting glass units turn the slot line into two adjacent addresses — inner lite in one slot, outer lite in the next — so the kit is complete before the trolley reaches IGU assembly, and which drawing lines decide whether that works.
A double-glazed unit is two lites, one of them usually coated, plus a spacer frame and desiccant. At the assembly table both lites have to be within arm’s reach at the same moment, because the first one is already tilted, cleaned and registered against the frame when the second is lifted into place. If the outer lite is not there, the inner lite does not go back on the rack politely. It has been unloaded, inspected and handled, and it now sits in the shop as stranded work in progress waiting for a partner sheet that may still be behind a tempering load.
Most plants do not lose that sheet. They bury it. Sheeting comes off the cutting table in nesting order, the A-frame or the wall bay is filled front to back, and retrieval runs last in, first out — so the lite that was cut first is the one furthest from the aisle. A chipped lite, a re-cut, or a single missing sheet means every sheet in front of it gets moved twice, and the operator at the table is standing there holding its mate. The line does not stop because of glass breakage. It stops because of retrieval order.
Kitting on an IGU line is a slot decision, not a paperwork step
Kitting means the unit’s parts are picked and checked against the job before the pair reaches the table, so the assembly station only assembles. On a harp rack the physical form of that idea is one lite per slot: put the inner lite in slot 14 and the outer lite in slot 15 and the kit is a position pair, not a note on a work order. That is the difference between a rack that holds glass and harp racks for sorting glass units, and it only pays off if the operator can reach slot 15 without unloading slots 1 to 14 first — the random access property a stacked A-frame cannot give.

The rack as a physical database: the index does the scheduling
What makes a slot address usable is that it is readable without a screen. On this build a slot index sticker runs along the bottom front channel — numbers 1 to 23 on one machine, 05 to 18 on another, 57 to 74 on a high-density custom frame — printed under the black-and-white nylon roller shaft, so a person standing at the aisle reads the address off steel rather than off a pick list. Loading becomes the scheduling decision: the planner decides which job occupies which pair of slots at the moment of sheeting, and the retrieval decision disappears, because nothing is behind anything.
Capacity is a project number here, not a catalogue figure. Recorded builds run from 40 to 50 slots on a wide body and a narrower companion frame, through 60 and 84 slot configurations, to custom frames whose index scale passes slot 75. A glass WIP buffer rack sized to the kit count of one push keeps the pairing local; a rack sized to shift volume turns the pairing back into a search.
Pairing errors drop where the comparison happens at the slot
Wrong-lite errors on an IGU line are rarely a reading mistake. They happen when both lites are on the table, out of the rack, and the only thing distinguishing them is a sticker and memory. Move the comparison to the slot and the operator is looking at two adjacent sheets carrying the same job reference, at chest height, with the coated face already oriented. No vendor should quote a defect-rate reduction for that, and we do not. What changes is where the check occurs and how many times the sheet is touched — and the on-time effect follows from the fact that a missing outer lite is discovered at loading, while it can still be re-cut, instead of at the table, after the line has been staged.

Random access also depends on the pair being motionless while a hand goes in. The divider between slots is a steel wire rope in a PVC sleeve, so the contact face is polymer and a Low-E coating is not rubbing steel; slot width follows the lite, with 12 mm openings recorded for 6.36 to 12.7 mm sheets and 8 to 10 mm cut for 6 mm work; a bolted EPDM strip on the backrest takes the lean; and the foot-operated floor lock lifts the base onto fixed rubber blocks, so the mass stops standing on four casters and oil or a slope has no friction pair to spoil. On the lifting variant the lock bar raises the lites clear of the bottom rollers as the pedal goes down — the pair cannot slide sideways out of the slot while it is being picked.
Four things to send before the slot spacing is cut
- Both lite thicknesses and which face is coated. This sets slot width — we build 8 to 10 mm for thin lites, 12 mm, 14 mm, 14.3 mm or 25 mm per record, and an opening cut for the heavy end of the schedule is exactly what lets a 4 mm pair swing.
- Maximum and minimum lite size. A frame cut around the largest sheet can obstruct handling of the smallest, so both numbers belong on the drawing before base length is fixed.
- Kits per push. Unit count per trolley decides slot count and whether the build needs 40, 60, 84 or a frame past 75 slots; the wide body also sets the aisle width the trolley must turn in.
- Floor condition at the assembly table. Grinding water, cutting oil and a fall towards a drain joint decide lock stations and caster set — 5 inch or 8 inch polyurethane, two fixed and two swivel braked, with the mechanical floor lock doing the holding, not the brake.
Frame section, load figure and slot layout stay project values: Q235A carbon steel square tube, static powder coat over blasted steel, bolted joints so the frame ships flat and assembles on site. A 1500 × 1200 × 1805 mm build on record gives 1614 mm of storage height on 8 inch casters; load ratings in the files run from a 300 kg build on 60 lites of 4 mm to a 1500 kg class, and a large custom build past 2500 kg, each one bound to its own drawing.