Glass fabrication workshop · vertical panel storage · irregular cuts
A triangular gable light or a tall trapezoid often leaves 100 mm of bottom edge to carry the whole sheet. On a roller rack that edge lands on one or two wheels and the rest of the line is air, which is exactly where the chips start. Here is what a full base harp rack does differently, and which two numbers we need before a drawing.
In a custom glass fabricator, the order book is full of shapes that do not help anyone: gable-end triangles for a residential roof-light, trapezoid spandrels under a stair, a 2.6 m high panel that is only 400 mm wide, arched tops that arrive with the bottom corners trimmed off. The cutting, edging and tempering side of the plant handles them fine. The problem lands after tempering, when that sheet has to stand somewhere until the truck comes.
An architectural door and window manufacturer meets the same wall from the other direction. Door leaves and frame panels are handled in a known width, but the moment the plant takes a bespoke facade package the sheet widths stop matching the rack. So the odd pieces get leaned against a wall, or laid flat on a timber stand, or carried by hand to the next bay. That is where the rack stops being a rack and becomes a risk assessment.
Why a Roller Rack Turns a Short Bottom Edge into a Chip
A roller rack is a set of discrete support stations at a fixed pitch along the base. That arrangement assumes a long bottom edge that bridges several stations at once, which is true for a standard 2440 x 1830 sheet and false for a shape whose bottom edge is the short side.
When the bottom edge is shorter than the roller pitch, the sheet is carried by one or two contact patches. Every kilogram of a tempered panel now passes through those patches instead of being spread along a line, and glass does not redistribute that concentration by yielding. The failure starts at the arris, on the very corner of the edge, and runs inward as a shell-shaped chip that removes the tempering margin.
The second half of the problem is the gap itself. Between the rollers the bottom edge is unsupported, so the sheet settles into the space by a few millimetres, leans, and then binds as soon as somebody pushes the rack. A narrow, tall panel makes this worse because the centre of gravity sits high: a small settlement at the base becomes a visible lean at the top, and the edge starts hunting along the roller flange or the bare steel beside it.

What a Full-Length Base Line Changes
On this double-sided A-frame glass rack the bottom support is not a row of stations. The base is a welded steel frame carrying a cradle line that runs along the working width of the rack, so the sheet does not have to find a station at all: it registers anywhere on that line. Set a 400 mm wide trapezoid on the frame and it takes the same continuous bearing as a full 2440 mm sheet, because the support belongs to the base rather than to a wheel position.
That line is lined, not bare. The cradle carries a 44 x 10 x 26 mm arc rubber strip seated in a C-channel, with roughly 10 mm flat rubber across the load-bearing faces and steel-embedded rubber pads on the contact path; the pads are bolted rather than glued so they stay on the frame through a few thousand panel cycles. The arc strip acts as a shallow trough, which is why the trimmed bottom corner can be pushed in smoothly instead of catching a steel lip. The load arrives on an area and on a line, not on a point.
The frame behind that line is Q235A carbon steel: a 60 x 3 mm base section on the recorded builds, C-channel uprights of 50 x 25 x 2 mm, 8# channel beams at 80 x 43 x 5 mm, and full seam welding on the main-frame nodes with bolted joints kept between the major parts for the return leg. The A-frame cradle angle is conventionally 90 degrees, and it matters for irregular glass support: the panel leans onto an angled face, so the bottom edge is loaded in compression along its length while the top edge is held by the limit press rod and the ratchet tie-down.
The Base Line, the Fork Channel and the Caster Set Are One Assembly
The reason the base can behave like a continuous line is that it also has to be the handling interface. Inside the same base rails sits a closed fork channel of about 164 x 92 mm internal, with recorded centres of 500 mm at the front and 600 mm at the side. A closed channel guides the tines and keeps them below the load, so a forklift handling rack for glass panels does not rely on the driver judging height under a sheet he cannot see.
The rest of the mobile side is specified with the base, not added later: a polyurethane caster set of 6 inch swivel-braked wheels at the steering end with fixed wheels behind on the recorded configuration, anti-tip legs standing 30 to 50 mm clear of the slab, integral top lifting eyelets for overhead handling, and a rubber-faced limit press rod plus a ratchet tie-down pulling on the top beam to close the pack. Bases, triangular supports and beams bolt apart and nest, so empty-rack return and storage do not ship the standing volume of a welded A-frame.

What to Send With the Enquiry, and What Each Answer Sets
- Shortest bottom edge and largest sheet outline — this sizes the cradle line and confirms that the short edge sits fully on the base rather than overhanging it.
- Unit weight and the number of sheets per side — this fixes the base section, the load figure written on the drawing, and whether the pad family needs a steel-embedded pad on the contact face.
- How the rack moves: by hand, by forklift, or by crane — this decides the caster set, the fork channel position, and whether lifting eyelets and anti-tip legs are part of the build.
- Storage width per side and maximum panel height — the two trade against each other at a 90 degree cradle; the recorded widths run from 180 to 420 mm, and a wider slot costs height on the same frame.
- Floor, aisle and turning space — this is what the anti-tip legs and caster diameter are chosen against, since a 30 to 50 mm clearance leg only helps on a hard, flat slab.
- Edge condition and any polymer slot board or liner you want between rubber and glass — this selects between the arc strip in the C-channel, flat rubber, or a lined slot, and it is confirmed per order rather than published as one standard.
For a plant that quotes bespoke shapes, the practical gain is not a bigger rack. It is that the odd panel enters the same vertical panel storage and internal material handling loop as everything else: one rack family, one pad specification, one handling method, and no one-off timber stillage built for a single gable light. The shape stops being the reason to turn an order down, and it stops being the reason a chip comes back from the fitting team.