The angle that drains condensate is the lean built into the A-frame, not a setting anyone changes on site. It only works when two other things are also true: the pads touch the bottom edge instead of the coated face, and the lean stays inside the geometry that keeps the rack from overturning. There is no single angle number for all panels, and a supplier who quotes one without asking your panel size is guessing.
Why a Low-E pane gets water marks in storage
A condensation mark is not a cleaning problem. When a cold panel comes into a warmer, more humid shop or warehouse, water condenses on the coated surface. If the pane stands dead vertical, that water film has nowhere to go. It sits on the coating, and under the weight of the sheet it is pressed against whatever is holding the panel: the rubber pad, the limit bar, or the next pane behind it. Soft-coat Low-E is a sputtered metal oxide layer, not a glass surface. Once moisture is held against it under pressure, the mark is in the coating rather than on it, and polishing does not take it out.
What the tilt actually does
The A-frame’s job is to give that water an exit. A small lean off vertical lets the condensate film break and run down the face to the bottom edge, where the base rail sheds it, instead of pooling along the line where the pad meets the panel. In glass plants the drainage lean is normally a few degrees off vertical; the band most shops work to is roughly 3 to 6 degrees.
On a double-sided A-frame that angle is set by the triangular support geometry of the frame itself. It is not a field adjustment, and it is not universal. The lean that drains a tall pane is not automatically right for a short one, and it has to be checked against the frame’s anti-overturning geometry at the same time. That is why the angle is drawn for your panel rather than copied from a catalogue.

Why the rubber pads only touch the bottom edge
The pad is not a cushion laid over a steel rail. The rubber strip is set into the C-channel and backed by a steel insert, so under panel weight it holds its section instead of flattening out and spreading across the coated face. Contact stays on a defined line at the bottom edge of the pane, where the glass is thickest and the coating is not doing optical work. That is the difference between a pad that protects and a pad that prints. The same edge-only rule applies to the limit bar, which presses on the edge zone of the panel rather than clamping the middle of the face.
The top restraint follows the same logic. A double-sided A-frame only drains while the panel keeps its lean, so the limit bar and the ratchet tie-down hold the pane against the frame so it cannot walk forward at the top and go vertical, or past vertical, on the next forklift cycle. Restraint is applied at the edges, the load is held, and the coated face is left alone.


Which way should the coated face go?
The working rule is coated face into the air gap, uncoated face against the pad. Soft-coat Low-E is the surface that marks, so it should face open air where condensate can run off, and never sit against rubber. If you load two panes back to back, keep the coated faces away from each other or separate them, because coated-to-coated contact plus trapped moisture is where the permanent marks come from.
Two cases change the answer, and both should be confirmed before the loading pattern is fixed. Hard-coat Low-E is far more forgiving than soft coat and tolerates contact that soft coat does not. A sealed insulating unit is a different case again, because the Low-E surface sits inside the cavity and the exposed faces are plain glass. Tell us which build-up you are storing and the contact line is set to the face that is actually at risk.
Damp storage: what else has to be in place
Tilt handles the water that reaches the face. It does not handle water that is trapped against the pane by something else, so the rest of the store has to cooperate.
- Take the wrap off before indoor storage. Stretch wrap is shipping protection, not storage protection; sealed around a cold load it traps the condensation you are trying to drain.
- Keep an air gap between panes. Panes pressed face to face hold water with no exit; a separator or a wider single-side storage setting keeps the faces apart.
- Use closed-cell, non-absorbing pad material and keep it dry. An open foam or a wet pad holds water against the coating.
- Do not store on a damp floor or in a wash-down bay. The rack runs on hardened, level floors, and the bottom edge needs to shed water rather than sit in a puddle.
- Let a cold load equalise. Panels off a cold truck into a warm shop condense on the face; move them somewhere ventilated rather than wrapping them again straight away.
- A dust cover keeps dust off, but a sealed cover over a cold load behaves the same way as wrap.
What we need before the angle can be drawn
Six inputs fix the frame lean, the pad contact line and the limit-bar position. Without them, any angle is a guess.
- Frame lean angle: panel height and width, single-side storage width, pad thickness. This decides whether the condensate film breaks and runs to the bottom edge or pools along the pad contact line.
- Pad contact line: which face carries the coating, and whether the pane is single, laminated or a sealed unit. This decides whether any rubber or steel touches the coated face at all.
- Coating orientation: coating type and the surface number in the build-up. This decides which surface faces the open air gap.
- Limit bar and tie-down setting: panel weight, panes per side, loading and unloading method. This decides whether the panel keeps its lean.
- Storage climate: heated shop or unheated warehouse, wash-down exposure, whether panels are wrapped in store. This decides how much water condenses on a cold panel.
- Handling method: forklift, crane or hand push, plus aisle width and floor condition. This decides whether the lean survives a handling cycle.
Where this does not apply
A steeper lean is not automatically better. Past a point it raises the overturning moment about the base and the casters, and the panel has to be restrained harder at the bottom to compensate. Tilt is therefore a trade-off between drainage and stability, and the drainage angle is never allowed to take priority over the anti-overturning geometry of the frame.
Two honest limits on the claim. First, a rack removes the trapped-water and hard-contact causes of marking; it does not make a coated pane immune to a wet, unventilated store, and we will not promise a zero-mark result. Second, this configuration suits upright storage of flat panels on a hardened, level floor with a defined handling method. It is not the right answer if panels have to be stored flat, if the store is permanently wet, or if the coating cannot be identified, because in those cases the contact line cannot be set to the face that is actually at risk.
Related reading on the same product: how side width is set so panels do not overhang the frame, how a mixed 2 m and 4 m load is tiered on one frame, and why the lean and the side pick-off path have to be planned together.
Send your panel size, coating face and storage climate
The lean, the pad line and the limit-bar position are fixed from your panel size, single-side storage width, coating face and how the rack is moved. Give us those and the drawing comes back with the drainage angle set for your panel, still inside the frame’s anti-overturning geometry.